Rotork-Schischek contact worldwide Certification with highest protection classes Applications for chemistry, pharmacy and general industry Applications for HVAC systems, sewage plants, landfills, power plants Applications for FPSO, ship-building, offshore, onshore Rotork-Schischek – Home Rotork-Schischek – Home

Company

you are here

Products/Solutions

Explosion Proof

Application Areas

Service/Downloads

Contact

Products | Industrial binary switching sensors InBin.. Schischek GmbH ExplosionproofEx..Red..In..CT/OCT..

Industrial, Binary, Switching Sensors InBin for Safe Area
Protection class IP66 | not Explosion proof

InBin-P

Binary pressure/differential pressure switch ΔP
Low pressure sensor (Pressostat)

Description – Industrial, binary differential pressure switch (Pressostat) InBin-P..

  • Industrial, binary pressure switches (Pressostat) for HVAC systems, e.g. for differential pressure control for filter- or fan belt monitoring
  • No additional module in the panel required
  • No intrinsically safe wiring required
  • All parameters adjustable on site w/o additional tools/meas. devices
  • Industrial pressostat InBin-P-100 with differential pressure range from
    0 - 100 Pa allows an achievement of new applications with a smaller differential pressure range
  • Additionally the InBin-P-100 has an adjustable switch activation delay contact for applications which require a time-delayed fault indication, for example short opening of doors in clean room environment
  • Optional available in stainless steel or with offshore/marine coating

InBin-P..

0...100 Pa, 0...500 Pa, 0...5.000 Pa1-channel or 2-channel adjustable15.000 Pa...50.000 Pa24 VAC / DCPotential free switching contact adjustable per menuadjustable from 0...240 s (factory setting:
0 s = switch activation delay off)
LCD Backlight, defeatable
Switching status LEDs
IP 66 / Aluminium casting, coated-20°...+50°C, 0...95 %rHintegrated terminal boxL × W × H = 180 (CT = 187) × 107 × 66 mmL × W × H = 215 × 125 × 68 mm~ 1 kg / VA ~ 2,3 kg / CT ~ 1,1 kgSafe area1 InBin-P-100 only 1-channel

Delivery – InBin-P..

  • Pressure switch (Pressostat) with integrated terminal box
  • 3 × Tapping screw Ø 4,2 × 13 mm
  • 1 × Short circuit tube ca. 140 mm length

Special models – InBin-P... - 2

  • Pressure switch with two switching outputs (2 × potential free contacts)

Special model in stainless steel – InBin-P-...-VA

  • Stainless steel housing similar AISI 316, some parts nickel plated

Special model in stainless steel – InBin-P-...-OVA

  • Offshore version with aluminium housing, pressure conection and screws
    in seawater resistant robust stainless steel (similar AISI 316), M20 cable glands nickel-plated

Special model painted (coated) – InBin-P-...-CT

  • Aluminium housing offshore/marine coated, seawater resistant, cable
    glands nickel plated, screws in stainless steel
  • Learn more about ...Bin-P-CT

Special model painted (coated) – InBin-P-...-OCT

  • Offshore version with aluminium housing offshore/marine coated, seawater resistant, cable glands nickel plated, tubes for clamping ring
    Ø 6 mm and screws in stainless steel
  • Learn more about ...Bin-P-OCT

Accessories – InBin-P..

  • Mounting bracket for round air ducts up to Ø 600 mm
  • Installation kit with 2 m flexible pressure hose Ø 6 mm
  • Stainless steel pressure tube connection for 6 mm clamp fittings
  • M16 standard cable glands in brass nickel plated
  • M20 cable glands in brass nickel plated for armoured cables
    (Offshore applications)
  • Heating system InPolar for use with InBin sensors under low temperatures down to −40 °C
InBin-FR

Frost protection thermostat – binary °C

Description – Industrial, binary frost protection thermostat InBin-FR..

  • Industrial, binary frost protection thermostats for HVAC systems,
    e.g. frost protection monitoring of heating registers / heat exchangers
  • No additional module in the panel required
  • No intrinsically safe wiring required
  • Switch-point mechanically adjustable
  • Optional available in stainless steel or with offshore/marine coating

InBin-FR..

-10 °C...+15 °C1-stage (1-channel)3 meters or 6 meters24 VAC / DC~ 40 cm1 potential-free contactSwitching status with LEDsIP 66 / Aluminium casting, coated-20°...+50°C, 0...95 %rHintegrated terminal boxL × W × H = 180 (CT = 187) × 107 × 66 mmL × W × H = 215 × 125 × 68 mm~ 1 kg / VA ~ 2,3 kg / CT ~ 1,1 kgSafe area

Delivery – InBin-FR..

  • Frost protection thermostat with integrated terminal box and 3 m
    or 6 m capillary (depending on type)
  • 3 × Tapping screw Ø 4,2 × 13 mm

Special model in stainless steel – InBin-FR-...-VA

  • Stainless steel housing similar AISI 316, some parts nickel plated

Special model painted (coated) – InBin-FR-...-CT

  • Aluminium housing offshore/marine coated, seawater resistant, cable
    glands nickel plated, screws in stainless steel
  • Learn more about ...Bin-FR-CT

Accessories – InBin-FR..

  • Cappillary duct, assembly cramp and 4 assembly brackets for InBin-FR-3
  • Cappillary duct, assembly cramp and 8 assembly brackets for InBin-FR-6
  • Mounting bracket for round air ducts up to Ø 600 mm
  • M16 standard cable glands in brass nickel plated
  • M20 cable glands in brass nickel plated for armoured cables
    (Offshore applications)
  • Heating system InPolar for use with InBin sensors under low temperatures down to −40 °C
InBin-N

Fan belt monitoring, binary Umin¹
via contactless speed control

Description – Fan belt guard via speed control InBin-N..

  • Industrial, binary fan belt monitoring modul (V-belt guard) for
    HVAC systems, via speed control of fan drive shaft
  • No additional module in the panel required
  • No intrinsically safe wiring required
  • Switch-point in min¹ is digitally adjustable
  • Integrated, adjustable time switch relais
  • Optional available in stainless steel or with offshore/marine coating

InBin-N..

0...10.000 min¹1-stage or 2-stage, 50...10.000 min¹24 VAC / DCNamur transducer inductive, DIN 19234Potential free switching contact adjustable per menuLCD Backlight, defeatable
Switching status LEDs
IP 66 / Aluminium casting, coated-20°...+50°C, 0...95 %rHintegrated terminal boxL × W × H = 180 (CT = 187) × 107 × 66 mmL × W × H = 215 × 125 × 68 mm~ 1 kg / VA ~ 2,3 kg / CT ~ 1,1 kgSafe area

Delivery – InBin-N..

  • Fan belt monitoring modul with integrated terminal box and directly mountable Namur transducer
  • 3 × Tapping screw Ø 4,2 × 13 mm

Special models – InBin-N-2

  • Version with 2-stage switch point (2 × potential-free contacts)

Special model in stainless steel – InBin-N-...-VA

  • Stainless steel housing similar AISI 316, some parts nickel plated

Special model painted (coated) – InBin-N-...-CT

  • Aluminium housing offshore/marine coated, seawater resistant, cable
    glands nickel plated, screws in stainless steel
  • Learn more about ...Bin-N-CT

Accessories – InBin-N..

  • Mounting set for Namur transducer onto ventilators/propellers up to approx. 20.000 m³/h (Empirical values – they can vary depending on the construction of ventilator/propeller)
  • Mounting set for Namur transducer onto ventilators/propellers over
    approx. 20.000 m³/h (Empirical values...)
  • Mounting bracket for round air ducts up to Ø 600 mm
  • M16 standard cable glands in brass nickel plated
  • M20 cable glands in brass nickel plated for armoured cables
    (Offshore applications)
  • Heating system InPolar for use with InBin sensors under low temperatures down to −40 °C
InBin-D

Thermostat / Hygrostat – binary °C %rH

Description – Industrial, binary thermostat / hygrostat InBin-D..

  • Industrial, binary module for connection of one InPro-B.. sensor
    probe, use as thermostat or hygrostat in HVAC systems
  • No additional module in the panel required
  • No intrinsically safe wiring required
  • Selectable on site if used for room or duct application
  • Switch-point for °C and %rH is separately adjustable (dependent on
    sensor probe type)
  • Adjustable directly on site without additional tools / meas. devices
  • Optional available in stainless steel or with offshore/marine coating

InBin-D..

-40 °C...+125 °C0...100 %rHRoom- and / or Duct-measurement24 VAC / DC1 × InPro-B.. sensor probePotential free switching contact adjustable per menuLCD Backlight, defeatable
Switching status LEDs
IP 66 / Aluminium casting, coated-20°...+50°C, 0...95 %rHintegrated terminal boxL × W × H = 180 (CT = 187) × 107 × 66 mmL × W × H = 215 × 125 × 68 mm~ 1 kg / VA ~ 2,3 kg / CT ~ 1,1 kgSafe area

Delivery – InBin-D..

  • Module (Thermostat/Hygrostat) with integrated terminal box and socket
    for one InPro-B.. sensor probe
  • 3 × Tapping screw Ø 4,2 × 13 mm
  • Required accessory: InPro-B.. sensor probe

Special models – InBin-D-2

  • Module with 4-stage output (4 pot.-free contacts = 2 × °C, 2 × %rH)

Special model in stainless steel – InBin-D-...-VA

  • Stainless steel housing similar AISI 316, some parts nickel plated

Special model painted (coated) – InBin-D-...-CT

  • Aluminium housing offshore/marine coated, seawater resistant, cable
    glands nickel plated, screws in stainless steel
  • Learn more about ...Bin-D-CT

Accessories – InBin-D..

  • InPro-B.. sensors
  • Mounting bracket for round air ducts up to Ø 600 mm
  • M16 standard cable glands in brass nickel plated
  • M20 cable glands in brass nickel plated for armoured cables
    (Offshore applications)
  • Heating system InPolar for use with InBin sensors under low temperatures down to −40 °C
InPro-B.. sensors, suitable for InBin-D Thermostat/Hygrostat
InBin-A

Switching modules – binary °C %rH ΔP

Description – Industrial, binary switching module InBin-A..

  • Industrial, binary switching modules for direct mounting in safe area
  • Use in HVAC systems (Heating, Ventilating and Air Conditioning)
  • Connection of 1, 2 or 5 passive, potential-free binary sensors
  • No additional module in the panel required
  • No intrinsically safe wiring required
  • Optional available in stainless steel or with offshore/marine coating

InBin-A..

24 VAC / DCThermostats TBR-2.., TBK.., TBT..
Humiditystats FBR-2G.., FBK-2G..
Diff. pressure switch DBK..,
Air flow switch WFBK-2G..
Frost protection thermostat TBK-FR-2G..
Potential-free switching contactActual value indication LEDsIP 66 / Aluminium casting, coated-20°...+50°C, 0...95 %rHintegrated terminal boxL × W × H = 180 (CT = 187) × 107 × 66 mmL × W × H = 215 × 125 × 68 mm~ 1 kg / VA ~ 2,3 kg / CT ~ 1,1 kgSafe area

Delivery – InBin-A..

  • Switching module with socket for 1, 2 or 5 binary passive sensors
    (depending on type)
  • 3 × Tapping screw Ø 4,2 × 13 mm
  • Optional accessory: Binary passive sensors

Special model in stainless steel – InBin-A-...-VA

  • Stainless steel housing similar AISI 316, some parts nickel plated

Special model painted (coated) – InBin-A-...-CT

  • Aluminium housing offshore/marine coated, seawater resistant, cable
    glands nickel plated, screws in stainless steel
  • Learn more about ...Bin-A-CT

Accessories – InBin-A..

  • Mounting bracket for round air ducts up to Ø 600 mm
  • M16 standard cable glands in brass nickel plated
  • M20 cable glands in brass nickel plated for armoured cables
    (Offshore applications)
  • Heating system InPolar for use with InBin sensors under low temperatures down to −40 °C
back to Product choice
to the top

Schischek News

New content on Schischek Homepage

Colour Code

ATEX products for
zone 1, 2, 21, 22
(e.g. ExMax+LIN)

ATEX products for
zone 2, 22
(e.g. RedMax+LIN)

Products for
safe area
(e.g. InMax+LIN)

Offshore/Marine
Coated versions
(e.g. ..Bin..-CT / OCT)

Stainless steel versions AISI 316
(e.g. ExCos-V)