Rotork-Schischek contact worldwide Certification with highest protection classes Applications for chemistry, pharmacy and general industry Applications for HVAC systems, sewage plants, landfills, power plants Applications for FPSO, ship-building, offshore, onshore Rotork-Schischek – Home Rotork-Schischek – Home

Company

you are here

Products/Solutions

Explosion Proof

Application Areas

Service/Downloads

Contact

Products | Industrial analog sensors & transmitter InCos.. Schischek GmbH ExplosionproofEx..Red..In..CT/OCT..

Industrial, Analog, Electric Sensors and Transmitter InCos for Safe Area
Protection class IP66 | NOT explosion proof

InCos-V

Volume flow (Diff.pressure) transmitter ΔP

InCos-V-CT with seawater resistant offshore/marine coating

Offshore/marine coated InCos-V-CT

Description – Industrial, analog volume flow IP66 transmitter InCos-V

  • Analog volume flow (differential pressure) transmitter for applications in safe area (industrial applications) for measuring and display of volume flows in ventilation systems (HVAC)
  • No additional module in the panel required
  • No intrinsically safe wiring required
  • Adjustable „k-factor“
  • Switch-on delay 3 seconds
  • Air volume and alarm monitoring
  • Additional switching contact
  • All parameters adjustable on site w/o additional tools/meas. devices
  • Integrated actual value indication, illuminated, can be switched off
  • Integrated terminal box
  • Robust aluminium housing with protection class IP66
  • Optional available in stainless steel or with offshore/marine coating

InCos-V

0...100 Pa / 0...300 PaDifferential pressure3 seconds24 VAC/DC1 × 0(4)...20 mA, 1 × 0(2)...10 V, 1 × RelaisBacklight, defeatableIP66 / Aluminium casting, coated-20°...+50°C, 0...95 %rHover integrated terminal boxL × W × H = 180 (CT = 187) × 107 × 66 mmL × W × H = 215 × 125 × 68 mm~ 1 kg / VA ~ 2,3 kg / CT ~ 1,1 kgSafe area

Delivery – InCos-V..

  • 1 × Analog volume flow transmitter InCos-V with display and integrated terminal box
  • 3 × Tapping screw Ø 4,2 × 13 mm
  • 1 × Short circuit tube ~ 140 mm length

Special model in stainless steel – InCos-V-...-VA

  • Stainless steel housing similar AISI 316, some parts nickel plated

Special model in stainless steel – InCos-V-...-OVA

  • Offshore version with aluminium housing, pressure conection and screws
    in seawater resistant robust stainless steel (similar AISI 316), M20 cable glands nickel-plated

Special model painted (coated) – InCos-V-...-CT

  • Aluminium housing offshore/marine coated, seawater resistant, cable
    glands nickel plated, screws in stainless steel

Special model painted (coated) – InCos-V-...-OCT

  • Offshore version with aluminium housing offshore/marine coated, seawater resistant, cable glands nickel plated, tubes for clamping ring
    Ø 6 mm and screws in stainless steel

Accessories – InCos-V..

  • Mounting bracket for round air ducts up to Ø 600 mm
  • Installation kit with 2 m flexible pressure hose Ø 6 mm
  • Stainless steel pressure tube connection for 6 mm clamp fittings
  • M16 standard cable glands in brass nickel plated
  • M20 cable glands in brass nickel plated for armoured cables
    (Offshore applications)
  • Heating system InPolar for use with InCos sensors under low temperatures down to −40 °C
InCos-P

Differential pressure sensors ΔP

Description – Industrial, analog differential pressure sensor InCos-P-..

  • Analog electric pressure sensors for HVAC systems, e.g. for differential pressure control in safe area
  • Volume flow applications optional
  • No additional module in the panel required
  • No intrinsically safe wiring required
  • All parameters adjustable on site w/o additional tools/meas. devices
  • Integrated actual value indication, illuminated, can be switched off
  • Integrated terminal box
  • Robust aluminium housing with protection class IP66
  • Optional available in stainless steel or with offshore/marine coating

InCos-P

± 100 Pa...± 7.500 Pa20 Pa25.000 Pa...120.000 Pa24 VAC / DC0-10 V DC, (0)4-20 mA, selectable on siteBacklight, defeatableIP66 / Aluminium casting, coated-20°...+50°C, 0...95 %rHover integrated terminal boxL × W × H = 180 (CT = 187) × 107 × 66 mmL × W × H = 215 × 125 × 68 mm~ 1 kg / VA ~ 2,3 kg / CT ~ 1,1 kgSafe area

Delivery – InCos-P..

  • 1 × Analog sensor InCos-P with integrated terminal box
  • 3 × Tapping screw Ø 4,2 × 13 mm
  • 1 × Short circuit tube ~ 140 mm length

Special models – InCos-P..-A

  • Module with one 4-20 mA output to connect external actual value indicator

Special model in stainless steel – InCos-P-...-VA

  • Stainless steel housing similar AISI 316, some parts nickel plated

Special model in stainless steel – InCos-P-...-OVA

  • Offshore version with aluminium housing, pressure conection and screws
    in seawater resistant robust stainless steel (similar AISI 316), M20 cable glands nickel-plated

Special model painted (coated) – InCos-P-...-CT

  • Aluminium housing offshore/marine coated, seawater resistant, cable
    glands nickel plated, screws in stainless steel
  • Learn more about ...Cos-P-CT

Special model painted (coated) – InCos-P-...-OCT

  • Offshore version with aluminium housing offshore/marine coated, seawater resistant, cable glands nickel plated, tubes for clamping ring
    Ø 6 mm and screws in stainless steel
  • Learn more about ...Cos-P-OCT

Accessories – InCos-P..

  • External LCD indicator connectable to InCos-P..-A sensors,
    mounting in safe area
  • Mounting bracket for round air ducts up to Ø 600 mm
  • Installation kit with 2 m flexible pressure hose Ø 6 mm
  • Stainless steel pressure tube connection for 6 mm clamp fittings
  • M16 standard cable glands in brass nickel plated
  • M20 cable glands in brass nickel plated for armoured cables
    (Offshore applications)
  • Heating system InPolar for use with InCos sensors under low temperatures down to −40 °C
InCos-D

Temperature-/humidity transmitter°C,%rH
Combination with InPro-C.. sensors

Description – Industrial, analog temperature / humidity transmitter InCos-D

  • Analog, electric transmitter for measurements of temperature and/or humidity together with InPro-C.. sensors in HVAC systems, installation in safe area
  • Connector for InPro-C.. sensors for room or duct mounting
  • No additional module in the panel required
  • No intrinsically safe wiring required
  • All parameters adjustable on site w/o additional tools/meas. devices
  • Integrated actual value indication, illuminated, can be switched off
  • Integrated terminal box
  • Robust aluminium housing with protection class IP66
  • Optional available in stainless steel or with offshore/marine coating

InCos-D

-40 °C...+125 °C0...100 %rHRoom- and / or Duct-measurement24 VAC / DC1 × InPro-C.. Sensor0-10 V DC, (0)4-20 mA, selectable on siteBacklight, defeatableIP66 / Aluminium casting, coated-20°...+50°C, 0...95 %rHover integrated terminal boxL × W × H = 180 (CT = 187) × 107 × 66 mmL × W × H = 215 × 125 × 68 mm~ 1 kg / VA ~ 2,3 kg / CT ~ 1,1 kgSafe area

Delivery – InCos-D..

  • 1 × Analog module InCos-D with integrated terminal box
  • 3 × Tapping screw Ø 4,2 × 13 mm
  • Required accessory: InPro-C.. Sensor

Special models – InCos-D-A

  • Module with two 4-20 mA outputs to connect external actual value
    indicator (Output 1 for °C, Output 2 for %rH)

Special model in stainless steel – InCos-D-...-VA

  • Stainless steel housing similar AISI 316, some parts nickel plated

Special model painted (coated) – InCos-D-...-CT

  • Aluminium housing offshore/marine coated, seawater resistant, cable
    glands nickel plated, screws in stainless steel
  • Learn more about ...Cos-D-CT

Accessories – InCos-D..

  • InPro-C.. sensors
  • External LCD indicator connectable to InCos-D-A transmitter,
    mounting in safe area
  • Mounting bracket for round air ducts up to Ø 600 mm
  • Sensor extension cable 3 m
  • M16 standard cable glands in brass nickel plated
  • M20 cable glands in brass nickel plated for armoured cables
    (Offshore applications)
  • Heating system InPolar for use with InCos sensors under low temperatures down to −40 °C
InPro-C.. sensors, compatible with InCos-D transmitter
InCos-A

Temperature-/humidity transmitter°C, %rH
Combination with passive sensors

Description – Industrial, analog temperature / humidity transmitter InCos-A

  • Analog, electric transmitter for measurements of temperature or humidity together with analog passive sensors in HVAC systems, module installation in safe area
  • Connector for one analog passive sensor for room or duct mounting
  • No additional module in the panel required
  • No intrinsically safe wiring required
  • All parameters adjustable on site w/o additional tools/meas. devices
  • Integrated actual value indication, illuminated, can be switched off
  • Integrated terminal box
  • Robust aluminium housing with protection class IP66
  • Optional available in stainless steel or with offshore/marine coating

InCos-A

24 VAC / DCAnalog, passive, potential free:
Pt 100, Pt 500, Pt 1000, Ni 100, Ni 200,
Ni 500, Ni 1000, Ni 1000 Siemens, KP 250, Resistance output 0...1 kOhm, 0...10 kOhm
0-10 V DC, (0)4-20 mA, selectable on siteBacklight, defeatableIP66 / Aluminium casting, coated-20°...+50°C, 0...95 %rHover integrated terminal boxL × W × H = 180 (CT = 187) × 107 × 66 mmL × W × H = 215 × 125 × 68 mm~ 1 kg / VA ~ 2,3 kg / CT ~ 1,1 kgSafe area

Delivery – InCos-A..

  • 1 × Analog sensor InCos-A with integrated terminal box
  • 3 × Tapping screw Ø 4,2 × 13 mm
  • Required accessory: passive sensor

Special models – InCos-A-A

  • Module with one additional 4-20 mA output to connect a external actual value indicator

Special model in stainless steel – InCos-A-...-VA

  • Stainless steel housing similar AISI 316, some parts nickel plated

Special model painted (coated) – InCos-A-...-CT

  • Aluminium housing offshore/marine coated, seawater resistant, cable
    glands nickel plated, screws in stainless steel
  • Learn more about ...Cos-A-CT

Accessories – InCos-A..

  • External LCD indicator connectable to InCos-A-A transmitter,
    mounting in safe area
  • Mounting bracket for round air ducts up to Ø 600 mm
  • M16 standard cable glands in brass nickel plated
  • M20 cable glands in brass nickel plated for armoured cables
    (Offshore applications)
  • Heating system InPolar for use with InCos sensors under low temperatures down to −40 °C
back to Product choice
to the top

Schischek News

New content on Schischek Homepage

Colour Code

ATEX products for
zone 1, 2, 21, 22
(e.g. ExMax+LIN)

ATEX products for
zone 2, 22
(e.g. RedMax+LIN)

Products for
safe area
(e.g. InMax+LIN)

Offshore/Marine
Coated versions
(e.g. ..Bin..-CT / OCT)

Stainless steel versions AISI 316
(e.g. ExCos-V)