Products/Solutions | Overview
Electric Actuators, Sensors, Controller and Components for HVAC Applications (Heating, Ventilation, Air-Conditioning)
All devices available for hazardous locations or safe area (depending on application and type)
- ExMax zone 1, 2, 21, 22 / RedMax zone 2, 22
- InMax for industry (no Ex-protection)
- Size S: 5...30 Nm
- Size M: 30...150 Nm
- Explosion proof for all gases and dust
- Certified acc. ATEX, IECEx and others
- Alu housing (V4A optional), IP66/IP67
- 24-240 VAC/DC power supply
- with or w/o spring return (~1/3/10/20 sec.)
- On-Off, 3-pos, 0-10 VDC, 4-20 mA
- integrated heater (−40°C)
- ExMax+LIN zone 1, 2, 21, 22 / RedMax+LIN
zone 2, 22 / InMax+LIN for safe area - Forces: 500...3.000 N
- Strokes: 7,5 / 10 / 15 / 20 / 30 / 42 mm
- Explosion proof for all gases and dust
- Certified acc. ATEX, IECEx and others
- 24-240 VAC/DC power supply
- On-Off, 3-pos, 0-10 VDC, 4-20 mA
- Alu housing, protection class IP66/IP67
- integrated heater (−40°C)
- ExRun zone 1, 2, 21, 22 / RedRun zone 2, 22
- InRun for the industry (no Ex-protection)
- Forces: 500...10.000 N
- Stroke: 5...60 mm
- Explosion proof for all gases and dust
- Certified acc. ATEX, IECEx and others
- 24-240 VAC/DC power supply
- On-Off, 3-pos, 0-10 VDC, 4-20 mA
- Alu housing, protection class IP66
- integrated heater (−40°C)
- ExReg-V zone 1, 2, 21, 22
- InReg-V for industrial applications (no Ex)
- Measurement range 0...100/300/1.000 Pa
- Suitable 90° control actuator available
- Explosion proof for all gases and dust
- Certified according ATEX and IECEx
- Fewer components
- No intrinsic safe electrical circuit necessary
- configureable directly on site in Ex area
- integral PID loop
- Alu housing, IP66
- ExCos zone 1, 2, 21, 22 / RedCos zone 2, 22
- InCos for the industry (no Ex-protection)
- Max. range −40°C...+125°C / 0...100%rH
- ΔP ±20 Pa up to ±7.500 Pa
- Explosion proof for all gases and dust
- Certified acc. ATEX, IECEx and others
- No intrinsic safe electrical circuit necessary
- No modul in the control-panel necessary
- Room- or duct mounting (selectable)
- Output 0-10 VDC, 4-20 mA
- Alu housing, IP66
- ExBin zone 1, 2, 21, 22 / RedBin zone 2, 22
- InBin for the industry (no Ex-protection)
- Explosion proof for all gases and dust
- Certified acc. ATEX, IECEx and others
- No intrinsic safe electrical circuit necessary
- No modul in the control-panel necessary
- 24 VAC/DC, switch-point selectable
- Room- or duct mounting (selectable)
- Output relais, potential-free contact
- Alu housing, IP66
- Integrated (Ex-e) terminal box
- EXL-IM-9182 analog Ex-i transmitter
- EXL-IR-9170 binary switching Ex-i module
- ExSens, passive sensors with manufacturer certification according ATEX 2014/34/EU
- Explosion proof for all gases and dust
- Transmitter and switching module
for DIN rail mounting - 24 V DC power supply
- Installation module: safe area
- Installation sensor: Ex area
- ExMag door holder magnets
for Ex zone 1, 2, 21, 22 - Forces: 650 N, 1.300 N, 2.000 N
- Explosion proof for all gases and dust
- Certified acc. ATEX, IECEx, DNV-GL
- 24 VDC power supply necessary
- Protection class IP65
- Components silicone free
- Cable halogen (and silicone) free