Rotork-Schischek contact worldwide Data sheets and certification Applications for chemistry, pharmacy and general industry Applications for HVAC systems, sewage plants, landfills, power plants Applications for FPSO, ship-building, offshore, onshore Schischek – Home Schischek – Home

Company

you are here

Products/Solutions

Explosion Proof

Application Areas

Service/Downloads

Contact

Products | Analog sensors & transmitter ExCos.. Schischek GmbH ExplosionproofEx..Red..In..CT/OCT..

Analog, Electric Sensors and Transmitter ExCos.. for Hazardous Locations
ATEX 2014/34/EU | Explosion proof | zone 1, 2, 21, 22

ExCos-P..

Differential pressure sensors ΔP

Description – Analog differential pressure sensor ExCos-P..

  • Analog electric pressure sensors ExCos-P.. for HVAC systems, e.g. for differential pressure control in hazardous locations zone 1, 2, 21, 22
  • Volume flow applications optional
  • No additional module in the panel required
  • No intrinsically safe wiring required
  • All parameters adjustable on site w/o additional tools/meas. devices
  • Integrated actual value indication, illuminated, can be switched off
  • Integrated Ex-e terminal box
  • Robust aluminium housing with protection class IP66
  • Optional available in stainless steel or with offshore/marine coating

ExCos-P..

± 100 Pa...± 7.500 Pa20 Pa25.000 Pa...120.000 Pa24 VAC / DC0-10 V DC, (0)4-20 mA, selectable on siteBacklight, defeatableIP66 / Aluminium casting, coated-20°...+50°C, 0...95 %rHover integrated terminal boxL × W × H = 180 (CT = 187) × 107 × 66 mmL × W × H = 215 × 125 × 68 mm~ 1 kg / VA ~ 2,3 kg / CT ~ 1,1 kgGases, mists, vapours, dustZone 1, 2, 21, 22ATEX, IECEx, EAC, KOSHA

Delivery – ExCos-P..

  • Analog sensor ExCos-P.. with integrated Ex-e terminal box
  • 3 × Tapping screw Ø 4,2 × 13 mm
  • 1 × Short circuit tube ~ 140 mm length

Special models – ExCos-P..-A

  • Module with one intrinsically 4..20 mA output to connect external actual value indicator

Special model in stainless steel – ExCos-P-...-VA

  • Stainless steel housing similar AISI 316, some parts nickel plated

Special model in stainless steel – ExCos-P-...-OVA

  • Offshore version with aluminium housing, pressure conection and screws
    in seawater resistant robust stainless steel (similar AISI 316), M20 cable glands nickel-plated

Special model painted (coated) – ExCos-P-...-CT

  • Aluminium housing offshore/marine coated, seawater resistant, cable
    glands nickel plated, screws in stainless steel
  • Learn more about ...Cos-P-CT

Special model painted (coated) – ExCos-P-...-OCT

  • Offshore version with aluminium housing offshore/marine coated, seawater resistant, cable glands nickel plated, tubes for clamping ring
    Ø 6 mm and screws in stainless steel
  • Learn more about ...Cos-P-OCT

Accessories – ExCos-P..

  • Intrinsic, external LCD indicator connectable to ExCos-P..-A sensors, mounting in hazardous locations zone 1, 2, 21, 22
  • Mounting bracket for round air ducts up to Ø 600 mm
  • Installation kit with 2 m flexible pressure hose Ø 6 mm
  • Stainless steel pressure tube connection for 6 mm clamp fittings
  • M16 standard cable glands in brass nickel plated
  • M20 Ex-d cable glands in brass nickel plated for armoured cables
    (Offshore applications)
  • Heating system ExPolar for use with ExCos sensors under low temperatures down to −40 °C
ExCos-D..

Temperature-/humidity transmitter°C,%rH
Combination with ExPro-C.. sensors

Description – Analog temperature / humidity transmitter ExCos-D..

  • Analog electric transmitter ExCos-D.. for measurements of temperature and/or humidity together with ExPro-C.. sensors in HVAC systems, installation in hazardous locations zone 1, 2, 21, 22
  • Connector for ExPro-C.. sensors for room or duct mounting
  • No additional module in the panel required
  • No intrinsically safe wiring required
  • All parameters adjustable on site w/o additional tools/meas. devices
  • Integrated actual value indication, illuminated, can be switched off
  • Integrated Ex-e terminal box
  • Robust aluminium housing with protection class IP66
  • Optional available in stainless steel or with offshore/marine coating

ExCos-D..

-40 °C...+125 °C0...100 %rHRoom- and / or duct measurement24 VAC / DC1 × ExPro-C.. Sensor0-10 V DC, (0)4-20 mA, selectable on siteBacklight, defeatableIP66 / Aluminium casting, coated-20°...+50°C, 0...95 %rHover integrated terminal boxL × W × H = 180 (CT = 187) × 107 × 66 mmL × W × H = 215 × 125 × 68 mm~ 1 kg / VA ~ 2,3 kg / CT ~ 1,1 kgGases, mists, vapours, dustZone 1, 2, 21, 22ATEX, IECEx, EAC, KOSHA

Delivery – ExCos-D..

  • Analog module ExCos-D.. with integrated Ex-e terminal box
  • 3 × Tapping screw Ø 4,2 × 13 mm
  • Required accessory: ExPro-C.. Sensor

Special model in stainless steel – ExCos-D-...-VA

  • Stainless steel housing similar AISI 316, some parts nickel plated

Special model painted (coated) – ExCos-D-...-CT

  • Aluminium housing offshore/marine coated, seawater resistant, cable
    glands nickel plated, screws in stainless steel
  • Learn more about ...Cos-D-CT

Accessories – ExCos-D..

  • ExPro-C.. sensors
  • Mounting bracket for round air ducts up to Ø 600 mm
  • Sensor extension cable 3 m
  • M16 standard cable glands in brass nickel plated
  • M20 Ex-d cable glands in brass nickel plated for armoured cables
    (Offshore applications)
  • Heating system ExPolar for use with ExCos sensors under low temperatures down to −40 °C
ExPro-C.. sensors, compatible with ExCos-D / RedCos-D transmitter
back to Product choice
to the top

Schischek News

New content on Schischek Homepage

Colour Code

ATEX products for
zone 1, 2, 21, 22
(e.g. ExMax)

ATEX products for
zone 2, 22
(e.g. RedMax)

Products for
safe area
(e.g. InMax)

Offshore/Marine
Coated versions
(e.g. ..Bin..-CT / OCT)

Stainless steel versions AISI 316
(e.g. ExCos-P)