Rotork-Schischek contact worldwide Data sheets and certification Applications for chemistry, pharmacy and general industry Applications for HVAC systems, sewage plants, landfills, power plants Applications for FPSO, ship-building, offshore, onshore Schischek – Home Schischek – Home

Company

you are here

Products/Solutions

Explosion Proof

Application Areas

Service/Downloads

Contact

Products | Binary electric switching sensors RedBin.. Schischek GmbH ExplosionproofEx..Red..In..CT/OCT..

Binary, Electric, Switching Sensors RedBin for Ex-Areas
ATEX 2014/34/EU | Explosion proof | zone 2, 22

RedBin-P

Binary pressure/differential pressure switch ΔP
Low pressure sensor (Pressostat)

Description – Binary, differential pressure switch (Pressostat) RedBin-P..

  • Binary, electric pressure switch (Pressostat) RedBin-P.. for HVAC systems, e.g. for differential pressure control for filter- or fan belt monitoring
  • No additional module in the panel required
  • No intrinsically safe wiring required
  • All parameters adjustable on site w/o additional tools/meas. devices
  • Pressostat RedBin-P-100 with differential pressure range from 0 - 100 Pa allows an achievement of new applications with a smaller differential pressure range
  • Additionally the RedBin-P-100 has an adjustable switch activation delay contact for applications which require a time-delayed fault indication, for example short opening of doors in clean room environment
  • Optional available in stainless steel or with offshore/marine coating

RedBin-P..

0...100 Pa, 0...500 Pa, 0...5.000 Pa1-channel or 2-channel adjustable15.000 Pa...50.000 Pa24 VAC / DCPotential free switching contact adjustable per menuadjustable from 0...240 s (factory setting:
0 s = switch activation delay off)
LCD Backlight, defeatable
Switching status LEDs
IP66 / Aluminium casting, coated-20°...+50°C, 0...95 %rHintegrated terminal boxL × W × H = 180 (CT = 187) × 107 × 66 mmL × W × H = 215 × 125 × 68 mm~ 1 kg / VA ~ 2,3 kg / CT ~ 1,1 kgGases, mists, vapours, dustZone 2, 22ATEX, EAC, CSA1 RedBin-P-100 only 1-channel

Delivery – RedBin-P..

  • Pressure switch (Pressostat) RedBin-P.. with integrated terminal box
  • 3 × Tapping screw Ø 4,2 × 13 mm
  • 1 × Short circuit tube ca. 140 mm length

Special models – RedBin-P... - 2

  • Pressure switch with two switching outputs (2 × potential free contacts)

Special model in stainless steel – RedBin-P-...-VA

  • Stainless steel housing similar AISI 316, some parts nickel plated

Special model in stainless steel – RedBin-P-...-OVA

  • Offshore version with aluminium housing, pressure conection and screws
    in seawater resistant robust stainless steel (similar AISI 316), M20 cable glands nickel-plated

Special model painted (coated) – RedBin-P-...-CT

  • Aluminium housing offshore/marine coated, seawater resistant, cable
    glands nickel plated, screws in stainless steel
  • Learn more about ...Bin-P-CT

Special model painted (coated) – RedBin-P-...-OCT

  • Offshore version with aluminium housing offshore/marine coating, seawater resistant, cable glands nickel plated, tubes for clamping ring
    Ø 6 mm and screws in stainless steel
  • Learn more about ...Bin-P-OCT

Accessories – RedBin-P..

  • Mounting bracket for round air ducts up to Ø 600 mm
  • Installation kit with 2 m flexible pressure hose Ø 6 mm
  • Stainless steel pressure tube connection for 6 mm clamp fittings
  • M16 standard cable glands in brass nickel plated
  • M20 Ex-d cable glands in brass nickel plated for armoured cables
    (Offshore applications)
  • Heating system ExPolar for use with RedBin sensors under low temperatures down to −40 °C
RedBin-FR

Frost protection thermostat – binary °C

Description – Binary, electric frost protection thermostat RedBin-FR..

  • Binary, electric frost protection thermostat RedBin-FR.. for HVAC systems, e.g. frost protection monitoring of heating registers / heat exchangers
  • No additional module in the panel required
  • No intrinsically safe wiring required
  • Switch-point mechanically adjustable
  • Optional available in stainless steel or with offshore/marine coating

RedBin-FR..

-10 °C...+15 °C1-stage (1-channel)3 meters or 6 meters24 VAC / DC~ 40 cm1 potential-free contactSwitching status with LEDsIP66 / Aluminium casting, coated-20°...+50°C, 0...95 %rHintegrated terminal boxL × W × H = 180 (CT = 187) × 107 × 66 mmL × W × H = 215 × 125 × 68 mm~ 1 kg / VA ~ 2,3 kg / CT ~ 1,1 kgGases, mists, vapours, dustZone 2, 22ATEX, EAC, CSA

Delivery – RedBin-FR..

  • Frost protection thermostat RedBin-FR.. with integrated terminal box and
    3 m or 6 m capillary (depending on type)
  • 3 × Tapping screw Ø 4,2 × 13 mm

Special model in stainless steel – RedBin-FR-...-VA

  • Stainless steel housing similar AISI 316, some parts nickel plated

Special model painted (coated) – RedBin-FR-...-CT

  • Aluminium housing offshore/marine coated, seawater resistant, cable
    glands nickel plated, screws in stainless steel
  • Learn more about ...Bin-FR-CT

Accessories – RedBin-FR..

  • Cappillary duct, assembly cramp and 4 assembly brackets for RedBin-FR-3
  • Cappillary duct, assembly cramp and 8 assembly brackets for RedBin-FR-6
  • Mounting bracket for round air ducts up to Ø 600 mm
  • M16 standard cable glands in brass nickel plated
  • M20 Ex-d cable glands in brass nickel plated for armoured cables
    (Offshore applications)
  • Heating system ExPolar for use with RedBin sensors under low temperatures down to −40 °C
RedBin-D

Thermostat / Hygrostat – binary °C %rH

Description – Binary, electric thermostat / hygrostat RedBin-D..

  • Binary, electric module RedBin-D.. for connection of one ExPro-B.. sensor, use as thermostat or hygrostat in HVAC systems in zone 2, 22
  • No additional module in the panel required
  • No intrinsically safe wiring required
  • Selectable on site if used for room or duct application
  • Switch-point for °C and %rH is separately adjustable (depending on
    sensor type)
  • Adjustable directly on site without additional tools / meas. devices
  • Optional available in stainless steel or with offshore/marine coating

RedBin-D..

-40 °C...+125 °C0...100 %rHRoom- and / or Duct-measurement24 VAC / DC1 × ExPro-B.. sensorPotential free switching contact adjustable per menuLCD Backlight, defeatable
Switching status LEDs
IP66 / Aluminium casting, coated-20°...+50°C, 0...95 %rHintegrated terminal boxL × W × H = 180 (CT = 187) × 107 × 66 mmL × W × H = 215 × 125 × 68 mm~ 1 kg / VA ~ 2,3 kg / CT ~ 1,1 kgGases, mists, vapours, dustZone 2, 22ATEX, EAC, CSA

Delivery – RedBin-D..

  • Module (Thermostat/Hygrostat) RedBin-D.. with integrated terminal box and socket for one ExPro-B.. sensor
  • 3 × Tapping screw Ø 4,2 × 13 mm
  • Required accessory: ExPro-B.. sensor

Special models – RedBin-D-2

  • Module with 4-stage output (4 pot.-free contacts = 2 × °C, 2 × %rH)

Special model in stainless steel – RedBin-D-...-VA

  • Stainless steel housing similar AISI 316, some parts nickel plated

Special model painted (coated) – RedBin-D-...-CT

  • Aluminium housing offshore/marine coated, seawater resistant, cable
    glands nickel plated, screws in stainless steel
  • Learn more about ...Bin-D-CT

Accessories – RedBin-D..

  • ExPro-B.. sensors
  • Mounting bracket for round air ducts up to Ø 600 mm
  • M16 standard cable glands in brass nickel plated
  • M20 Ex-d cable glands in brass nickel plated for armoured cables
    (Offshore applications)
  • Heating system ExPolar for use with RedBin sensors under low temperatures down to −40 °C
ExPro-B.. sensors, suitable for ExBin-D.. or RedBin-D.. Thermostat/Hygrostat
RedBin-A

Switching amplifier – binary °C %rH ΔP

Description – Binary, electric switching amplifier module RedBin-A..

  • Binary, electric switching amplifier modules RedBin-A.. for direct mounting in hazardous locations zone 2, 22
  • Use in HVAC systems (Heating, Ventilating and Air Conditioning)
  • Connection of 1 up to 2 passive, potential-free binary sensors
  • No additional module in the panel required
  • No intrinsically safe wiring required
  • Optional available in stainless steel or with offshore/marine coating

RedBin-A..

24 VAC / DCThermostats TBR-2.., TBK.., TBT..
Humiditystats FBR-2G.., FBK-2G..
Diff. pressure switch DBK..,
Air flow switch WFBK-2G..
Frost protection thermostat TBK-FR-2G..
Potential-free switching contactActual value indication LEDsIP66 / Aluminium casting, coated-20°...+50°C, 0...95 %rHintegrated terminal boxL × W × H = 180 (CT = 187) × 107 × 66 mmL × W × H = 215 × 125 × 68 mm~ 1 kg / VA ~ 2,3 kg / CT ~ 1,1 kgGases, mists, vapours, dustZone 2, 22Zone 0, 1, 2, 20, 21, 22ATEX, EAC, CSA

Delivery – RedBin-A..

  • Switching amplifier module RedBin-A.. with socket for 1 or 2 binary ExSens sensors (depending on amplifier type)
  • 3 × Tapping screw Ø 4,2 × 13 mm
  • Optional accessory: Binary sensors series ExSens

Special model in stainless steel – RedBin-A-...-VA

  • Stainless steel housing similar AISI 316, some parts nickel plated

Special model painted (coated) – RedBin-A-...-CT

  • Aluminium housing offshore/marine coated, seawater resistant, cable
    glands nickel plated, screws in stainless steel
  • Learn more about ...Bin-A-CT

Accessories – RedBin-A..

  • Mounting bracket for round air ducts up to Ø 600 mm
  • M16 standard cable glands in brass nickel plated
  • M20 Ex-d cable glands in brass nickel plated for armoured cables
    (Offshore applications)
  • Heating system ExPolar for use with RedBin sensors under low temperatures down to −40 °C
back to Product choice
to the top

Schischek News

New content on Schischek Homepage

Colour Code

ATEX products for
zone 1, 2, 21, 22
(e.g. ExMax)

ATEX products for
zone 2, 22
(e.g. RedMax)

Products for
safe area
(e.g. InMax)

Offshore/Marine
Coated versions
(e.g. ..Bin..-CT / OCT)

Stainless steel versions AISI 316