Products | PDF Data Sheets | Heating system ...Polar
Technical data sheets and certificates for download
Schischek is certified according to ISO 9001
and ATEX directive
ExMax, RedMax, InMax size S 90° Quarter turn actuators with/without spring return, 5-30 Nm |
ExMax, RedMax, InMax size M 90° Quarter turn actuators with/without spring return, 30-150 Nm |
ExMax + LIN, RedMax + LIN, InMax + LIN Linear valve actuators size "S" and "M" with spring return (for safety functions), 500-3.000 N |
ExRun, RedRun, InRun size S Valve actuators without spring return, 500-10.000 N |
ExReg-V, InReg-V Volume (air) flow controller (CAV, VAV), 0-1.000 Pa |
ExCos-P, RedCos-P, InCos-P Differential pressure/VAV-control sensors |
ExCos-D, RedCos-D, InCos-D Temperature-/humidity transmitter for one ExPro-C.. sensor (InCos-D in combination with InPro-C.. sensor) |
ExBin-P, RedBin-P, InBin-P Binary pressure-/differential pressure switches |
ExBin-FR, RedBin-FR, InBin-FR Binary frost protection thermostats |
ExBin-D, RedBin-D, InBin-D Binary thermostats/hygrostats for connection of one ExPro-B../InPro-B.. sensor (°C and/or %rH) |
ExBin-A, RedBin-A, InBin-A Binary modules for 1 or 2 passive, potential-free, switching ExSens sensors |
ExPolar, InPolar (MS, MM, CBR)
Heating system for use with Max actuators and Cos / Bin / Reg sensors and controllers under low temperatures |
info – Technical Data and Safety
Technical Datasheet |
|
Certificate |
|
EC Conformity Declaration |
ExPolar heating system
ExPolar heating system | Zone 1, 2, 21, 22 |
||||||
Type | Description | Tech. Data + Safety | ||||
---|---|---|---|---|---|---|
ExPolar-...-MS | Heating system for ExMax actuators size S for use under extreme temperatures down to − 50 °C | |||||
ExPolar-...-MM | Heating system for ExMax actuators size M for use under extreme temperatures down to − 50 °C | |||||
ExPolar-...-CBR | Heating system for ExCos/Bin/Reg sensors for use under extreme temperatures down to − 40 °C |
info – Technical Data and Safety
Technical Datasheet |
|
EC Conformity Declaration |
InPolar heating system
InPolar heating system | for safe area (no Ex-protection) |
||||||
Type | Description | Tech. Data + Safety | ||||
---|---|---|---|---|---|---|
InPolar-...-MS | Heating system for InMax actuators size S for use under extreme temperatures down to − 50 °C | |||||
InPolar-...-MM | Heating system for InMax actuators size M for use under extreme temperatures down to − 50 °C | |||||
InPolar-...-CBR | Heating system for InCos/Bin/Reg sensors for use under extreme temperatures down to − 40 °C |
EXL-IM-9182, EXL-IR-9170 (ExLine) Transmitter and switching modules with Ex-i safe circuit |
ExSens (Analog) Passive, analog sensors, compatible with transmitter EXL-IM-9182 |
ExSens (Binary) Passive, switching (binary) sensors, compatible with switch module ExBin-A, RedBin-A or EXL-IR-9170 |
ExMag (EXM) Electric door holder magnets |
Discontinued products (for info only):
ExBin-N, RedBin-N, InBin-N Binary fan belt monitoring modules via speed control Product discontinued |
ExCos-A, RedCos-A, InCos-A Temperature-/humidity transmitter for passive sensors Product discontinued |
EXL-IMU-1, EXL-IRU-1 (ExLine) Transmitter and switching modules with Ex-i safe circuit Product discontinued |
ExPlus, RedPlus, InPlus size S Linear actuators with long stroke, 300-3.000 N Product discontinued |
EXP Linear motion actuators Product discontinued |
ExTurn (EXT) Quarter turn actuators with spring return Product discontinued Follow-up model ExMax size M available. |
ExVent (EXV) Valve actuators with/without spring return Product discontinued Follow-up model ExRun size S available. |
NormPlus (NOP) Industrial linear actuators (IP65) Product discontinued |